Topic : An Improved Maximum Power Point Tracking Of Three Phase Grid Connected Based On Robust Nonlinear Controller
Authors:M.Sangeetha || C.Prasanna Kumari
Abstract:This paper presents a robust nonlinear controller design for a three-phase grid-connected photovoltaic (PV) system to control the current injected into the grid and the dc-link voltage for extracting maximum power from PV units. The controller is designed based on the partial feedback linearization approach, and the robustness of the proposed control scheme is ensured by considering structured uncertainties within the PV system model. An approach for modelling the uncertainties through the satisfaction of matching conditions is provided. The superiority of the proposed robust controller is demonstrated on a test system through simulation results under different system contingencies along with changes in atmospheric conditions. From the simulation results, it is evident that the robust controller provides excellent performance under various operating conditions.
Keywords: Grid-connected PV system, matching conditions, partial feedback linearization, robust nonlinear controller, structured uncertainty.
Download Paper
DOI: 01.1617/vol4/iss9/pid90618
Related Articles
Enhancement of Power Quality by Using DStatcom
Authors: Mr. S.S.Godhade || Mr.Amanulla Naikwade ,Miss.Archana Chavan, Mr.Swapnil Gaikwad Drives , Miss.Supriya Patsupe, Mr.Shivpratap Patil
Doi : 01.1617/vol4/iss2/pid72956
Volume4 ,February 2017.
Review & Study Paper of Vortex Windmill
Authors: Kushagra Gambhir || Divyesh Gothadiya,Masum Patel
Doi : 01.1617/vol4/iss2/pid78062
Volume4 ,February 2017.
Smart Automatic Energy Billing and Power Unplug System
Authors: N.Suriya || R.M.Bommi,J.Vijay, R.Narmadha, V.Malathi
Doi : 01.1617/vol4/iss4/pid56270
Volume4 ,April 2017.
Voltage Stability Improvement Using Static Var Compensators (SVC)
Authors: Shanti Chaturvedi ||
Doi : 01.1617/vol4/iss4/pid52430
Volume4 ,April 2017.
Power Quality in Distribution System using Automatic On-Load Tap Changer(Oltc)
Authors: V.Preethi || N.S.Priyanka,M.Mahalakshmi,G.Priyadarshini
Doi : 01.1617/vol4/iss4/pid14207
Volume4 ,April 2017.
Smart Library Book Management System
Authors: Madhur Gupta || Sneha Sanjay Jadhav,Vydeki D
Doi : 01.1617/vol4/iss5/pid92865
Volume4 ,May 2017.
Performance Analysis of IEEE 802.11 ac WLANS on Throughput and TXOP Sharing for MU MIMO WLANS
Authors: Shaik Khaja Mohiddin || Hemanth C
Doi : 01.1617/vol4/iss5/pid41309
Volume4 ,May 2017.
Performance Analysis of DVR Using Controller Parameter Optimization
Authors: Manish KR.Pandey || Dr.A.N.Tiwari
Doi : 01.1617/vol4/iss5/pid53961
Volume4 ,May 2017.
Human Skin as an Input Surface
Authors: Tarun K.Dalakoti || Shahrul, Addit anwar
Doi : 01.1617/vol4/iss6/pid38512
Volume4 ,June 2017.
“Vector Speed Control of Induction Motor using self-adjusting Fuzzy controller for Grain Drying System”
Authors: Ms. Ranjitha K. M || Dr. Rajashekar J. S
Doi : 01.1617/vol4/iss4/pid54230
Volume4 ,April 2017.